The Output service (OutputService) enables
you to merge XML form data with a form design created in LiveCycle
Designer to create a document output stream in one of the following
formats:
A PDF or PDF/A document output stream.
An Adobe PostScript output stream.
A Printer Control Language (PCL) output stream.
A Zebra Programming Language (ZPL) output stream.
The output stream can be sent to a network printer, a local printer,
or a disk file. When you use the Output service as part of a process,
you can also send the output stream to an email recipient as a file
attachment.
For details on the Output service, see Services Reference.
The following settings are available for the Output service.
- Transaction Type:
- Specifies how a transaction context should be propagated to
an operation:
- Required:
- supports a transaction context if one already exists; otherwise,
a new transaction context is created. This is the default value.
- Requires New:
- Always creates a new transaction context. If an active transaction
context exists, it is suspended.
- Transaction Time Out (in sec):
- The number of seconds that the underlying transaction provider
waits before rolling back a transaction that is wrapping this operation.
This value is ignored if an existing transaction context is propagated.
When
processing large data files or operating on a busy server, it may
be necessary to increase the Output service time out. To change
the time-out value, ensure that hardware servers have adequate memory
and that the memory is available to the Java Application Server
heap. The default value is 180.
|
|
|